WATTS 170 BLENDING VALVES
Bronze Body, Stainless Steel Disc
Female BSP connections
Temp range for 170H – 55 – 82ºC
Temp range for 170L – 38 – 55ºC
Min. flow requirement: 30-40 l/min
N.B. This is not an anti-scald valve
¾” 1″ 1¼” 1½” 2″
Watts 170 Blending Valve
|
 |
RWC HEATGUARD THERMOSTATIC MIXING VALVESTMV3 
Compression Ends – Irish or Metric
Hot temperature supply : 52°C – 90°C, 55°C – 60°C is recommended
Cold temperature supply : 5 – 20°C.
Temperature setting range : 38 to 46°C.
Maximum static pressure : 5 bar, Operating pressure : 0,2 to 5 bar.
Isolation valves – Not included in price
½”/15mm ¾”/22mm
RWC Heatguard Thermostatic Mixing Valve – TMV3
|
 |
WATTS ULTRAMIX THERMOSTATIC MIXING VALVE
For Multiple Showers
Temperature setting range: 10°C to 50°C
Max. hot water temperature : 85°C
Max. operating pressure : 10 bar.
Anti-scald protection : water shut off in less than 2 seconds
¾” x 56L ¾” x 80L 1″ x 120L 1¼” x 175L 1½” x 260L 2″ x 400L
Watts Ultramix Thermostatic Mixing Valve
|
 |
WATTS AQUAMIX THERMOSTATIC MIXING VALVE
4 set positions. Anti-scald protection.
Setting range: 32°C to 50°C. Max. differential pressure: 2 bar.
Female connections. Without internal check valves
Screwed BSP Female
½” ¾” 1″
Watts Aquamix Thermostatic Mixing Valve
|
 |
RWC THERMAL BALANCING VALVES 
DZR Brass Body
Female BSP
Temperature range: 35°C – 60°C
Pressure rating: PN10
Max. temperature: 100°C
½” ¾” Disinfection module Thermometer with adaptor
RWC Thermal Balancing Valve
|
 |
RWC FLOREG VALVE 
15mm compression ends
Isolating valve c/w strainers
Max. temperature: 100°C
Pressure rating: PN16
4 lpm 6 lpm 8 lpm 10 lpm 12 lpm 15 lpm
RWC Floreg Valve
|